The words you meet in the quote, in the price list and when we talk about your electrical installation. 54 words, explained in plain English.

A

Ampere
The unit of current, abbreviated A. A 10 A fuse lets 10 amperes through before it trips.
Authorised electrical installer
A person who has been granted authorisation by the Swedish National Electrical Safety Board, Elsäkerhetsverket. Every electrical installation company must have at least one authorised electrical installer attached to it. How to check an electrical company.

B

Back box
The box in the wall that holds a socket or a switch. Flush-mounted boxes sit inside the wall, surface-mounted boxes sit on the wall.

C

CEE socket
A round, sturdy socket for higher currents. Blue is single-phase 230 volts, red is three-phase 400 volts. Fixed prices for sockets.
Circuit
The sockets and lights that share one fuse in the consumer unit. If the fuse blows or trips, the whole circuit loses power. The cable from the fuse out to them is called a final circuit (gruppledning).
Circuit breaker
A fuse that switches off when the current gets too high and can be switched on again. Also called a miniature circuit breaker (MCB), dvärgbrytare in Swedish. Fuse box or circuit breakers.
Circuit chart
The list by the consumer unit that shows what each fuse supplies. It must be there, and it must be up to date.
Combined RCD and circuit breaker (RCBO)
A residual current device (RCD) and a circuit breaker in one unit. In Swedish it is also called personskyddsautomat. It is often used for a single circuit, for example the underfloor heating in a bathroom.
Consumer unit
The cabinet where the electricity in the house is divided into circuits. The consumer unit holds the main switch, the residual current device (RCD) and the fuses. In Swedish it is also called gruppcentral. More about replacing a consumer unit.
Corner box
A box of sockets that sits in the angle under the kitchen wall cupboards, so that the sockets end up by the worktop without being recessed into the wall. Electrics in the kitchen.

D

Dimmer
A switch that also controls the brightness. The dimmer must suit the type and wattage of the lamps. Fixed prices for switches and dimmers.
Downlight
A light fitting that is recessed into the ceiling and shines straight down. It needs a cavity above the ceiling. If it is permanently connected, an electrical installation company must connect it. Installing spotlights.

E

Earthed socket
A socket with protective earth, which you can see as two metal clips at the edge of the socket. In houses built in 1994 or later, all sockets must be earthed. Unearthed sockets.
Electrical installation company
A company that carries out electrical installation work for others. It must be registered with Elsäkerhetsverket, the Swedish National Electrical Safety Board, for the kinds of work it carries out. Our registration.
EV charger (wallbox)
A permanently mounted charger for an electric car, with its own circuit in the consumer unit and its own residual current device (RCD). Also called a charging station, laddstation in Swedish. More about EV chargers.
Extra-low voltage
A voltage of no more than 50 volts. You may build extra-low voltage lighting yourself if the transformer is no more than 200 VA, the current is limited to no more than 10 A and the transformer is connected with a plug. Installing spotlights.

F

Färdiganmälan
The completion notice: the notice the electrical installation company sends to the grid operator when work that was pre-notified is finished. More about meter cabinets and main fuses.
Föranmälan
The pre-notification: a notice to the grid operator before certain work is done, for example a new connection or a change of main fuse. It is filed by the electrical installation company. Pre-notification of an EV charger.

G

Grid operator
The company that owns the grid up to the house and the electricity meter. You can choose which company you buy electricity from, but not your grid operator: that is decided by where you live. Grid operators by municipality.
Grön teknik
The Swedish tax reduction for green technology, which covers EV chargers among other things. In 2026 it gives 50 per cent of the cost of labour and materials, up to SEK 50,000 per person per year. The green technology reduction for EV chargers.

I

IP rating
Two digits that show how well an electrical product withstands dust and water. In Swedish it is also called kapslingsklass. The closer to the shower and the bath, the higher the rating required. Electrics in the bathroom.

K

Kilowatt
The unit of power, abbreviated kW: how much electricity something is drawing at this moment. An 11 kW EV charger charges at 11 kilowatts. A kilowatt-hour, kWh, is the amount of electricity that has been used.
KNX
An open standard for controlling lighting, heating and other functions in a building from one shared system. More about smart homes.

L

LED driver
The unit that converts the 230 volts of the mains into what an LED lamp needs. You may connect an LED driver with a plug yourself. A permanently connected one must be connected by an electrical installation company. Installing spotlights.
Lighting outlet
The outlet in the ceiling or on the wall where a light is connected with a lamp plug. The standardised lighting outlet is called DCL. Fixed prices for lighting outlets.
Load balancing
A function that lowers the power of the EV charger when the rest of the house is using a lot of electricity, so that the main fuse does not trip. More about load balancing.
Local isolator switch
A switch next to a machine, a pump or a hot tub that lets the power be cut on the spot for servicing. More about controls and automation.

M

Main fuse
The fuses where the electricity comes into the house, before the electricity meter. The size, for example 16, 20 or 25 A, determines how much electricity the house can use at the same time. Raising the main fuse.
Main switch
The switch in the consumer unit that cuts the power to all the circuits at once.
Meter cabinet
The cabinet that holds the electricity meter and the main fuses. It can stand on the plot, be recessed into the outer wall or hang on the wall. More about meter cabinets.
Miniature circuit breaker (MCB)
The same thing as a circuit breaker (automatsäkring in Swedish): a fuse with a lever that switches off when the current is too high and can be switched on again.
Modular consumer unit
A consumer unit where the circuit breakers and switches are fitted as modules on a rail. The opposite is older units with screw-in fuses.
Module
The space a device takes up in a consumer unit. An ordinary circuit breaker is one module wide. A 1×13 consumer unit has one row with room for 13 modules. Fixed prices for consumer units.

N

Neutral
The conductor that carries the current back from the socket or the light. In a cable the neutral is blue. The technical term is neutral conductor.

P

Perilex socket
A three-phase socket for cookers and hobs that are connected with a plug. Fixed prices for sockets.
Permanent connection (hard-wired)
When an appliance is connected directly to the electrical installation without a plug, for example a cooker wired into a box. Permanently connecting an appliance, or disconnecting it, is electrical installation work. Connecting a cooker, hob and white goods.
Phase
The live conductor that carries the electricity to the socket or the light. A three-phase system has three phases.
Protective earth
The green-and-yellow conductor that carries the current away if a fault occurs in an appliance, so that the casing does not become live.

R

Residual current device (RCD)
A switch that cuts the power quickly when current leaks to earth, for example through a person. To protect people it must be marked 30 mA. More about residual current devices.
ROT-avdrag
The ROT deduction: a Swedish tax reduction for the labour cost of repairing, converting and extending a home you own. In 2026 it is 30 per cent, up to SEK 50,000 per person per year. The ROT deduction for electrical work.

S

Screw-in fuse
A fuse with a wire that melts through when the current is too high. A screw-in fuse that has blown is replaced with a new one of the same rated current. Fuse box or circuit breakers.
Self-inspection programme
The electrical installation company's own routines for making sure that the work is carried out according to the rules and is checked before the installation is put into use. The law requires every electrical installation company to have one.
Service cable
The cable that carries the electricity from the grid to the house and the meter cabinet. In Swedish it is also called serviskabel.
Single-phase
A connection with one phase and one neutral, 230 volts. Ordinary sockets and lights are single-phase. More about single-phase and three-phase.
Spotlight
A light fitting with directed light. It can be recessed into the ceiling or surface-mounted, on a track or on a spotlight bar. Installing spotlights.

T

Temporary site power
A temporary electricity connection to a building site, from a cabinet of its own with sockets and an electricity meter. How to arrange temporary site power.
Thermostat
It controls the heating so that a floor, for example, keeps the temperature you have set. You may replace an existing thermostat for no more than 16 A in its own box with an equivalent one, if you know how to do it. Underfloor heating and thermostats.
Three-phase
A connection with three phases, 400 volts between the phases. It is used for things that draw a lot of current, such as a cooker, an EV charger and larger motors. More about single-phase and three-phase.
Two-gang switch
A switch with two rockers that switch on two groups of lights separately, for example the two circuits in a chandelier.
Two-way switch
A switch that lets the same light be switched on and off from two places, for example at the bottom and the top of a staircase.

U

Unearthed socket
A socket without protective earth, common in dry rooms in older houses. It does not have to be replaced, but earthed and unearthed sockets must not be mixed in the same room. Unearthed sockets.

V

Visual inspection
A check where the installation is examined with the naked eye, without measuring instruments. It shows damage, wear and anything that looks wrong. More about the service plan.
Volt
The unit of voltage, abbreviated V. An ordinary socket has 230 volts.

W

Wifi access point
A transmitter for the wireless network that is connected with a network cable. It is often fitted in the ceiling and gives wifi where the router does not reach. More about data and networks.