Replacing a consumer unit

We replace old fuse boxes with screw-in fuses (proppskåp) and older consumer units with a new unit with circuit breakers. A Hager Gamma with one row and 13 modules costs SEK 5,810 installed, or SEK 4,780 with the Swedish ROT tax deduction for labour on your home (ROT-avdrag).

Close-up of breakers on a rail in an electrical cabinet

What it costs to replace a consumer unit

A new Hager Gamma 1×13 consumer unit costs SEK 5,810 installed, or SEK 4,780 with the Swedish ROT tax deduction for labour on your home (ROT-avdrag). Materials, installation and 25 per cent VAT are included. A travel charge of SEK 500 is added.

Larger units cost more. A Hager Gamma 2×13 costs SEK 8,627, or SEK 7,079 with ROT. A unit with four rows and 52 modules costs SEK 13,794, or SEK 11,214 with ROT. There are also units rated IP65 from Spelsberg, which are protected against water jets.

The prices apply to a standard installation: the unit sits where it can be reached and the existing cable route can be used. Fault-finding in the existing installation is not included, and extra work may be added if the installation has faults. Accessories such as a residual current device (RCD), a main switch and individual circuit breakers have their own lines in the list.

All sizes are listed under fixed prices for consumer units, and there is more about the price in the guide what it costs to replace a consumer unit. The price with ROT is the price after the deduction, if you are entitled to it.

What size of consumer unit you need

The designation 1×13 means one row with room for 13 modules, and 2×18 means two rows with 18 modules in each. A module is the width of a single-pole circuit breaker. A three-pole breaker, like the one for a cooker or a three-phase EV charger (wallbox), takes three modules. A four-pole RCD takes four.

The size is decided by:

  • how many circuits the home has today. A circuit is the sockets and lights that share one fuse.
  • which three-phase appliances you have or are planning, such as a cooker, heat pump or charger
  • whether the unit is to have one RCD or several
  • how much room you want to keep for the future.

A unit that is full cannot take new circuits without being extended or replaced. Allow for spare modules if you are planning a charger, a new kitchen or an extension to the house. Send us a photo of the present unit with the door open, and we will work out which size fits.

Fuse box or circuit breakers

An old fuse box with screw-in fuses (proppskåp) is not illegal and does not have to be replaced. According to the Swedish National Electrical Safety Board, Elsäkerhetsverket, an electrical installation must meet the requirements that applied when it was installed, and it need not be replaced just because it is old. What you alter or add, on the other hand, must follow today’s rules.

The difference between the two types is how the fuse is reset. A screw-in fuse that has blown is spent and is replaced with a new one of the same rated current: 6 A is green, 10 A red and 16 A grey. A circuit breaker, also called a miniature circuit breaker (MCB), trips and can be switched back on once the fault has been put right.

There can still be reasons to replace it:

  • the unit is full and you need more circuits
  • the house is getting a charger, a new kitchen or other large loads
  • you want an RCD and the old unit has no room for one
  • the fuse carriers (the screw caps that hold the fuses) get warm. If they are too hot to touch, and it does not pass, you should consult an electrical installation company (elinstallationsföretag), according to Elsäkerhetsverket.

The guide fuse box or circuit breakers helps you decide whether it is time.

RCD when the consumer unit is replaced

There is no requirement to fit an RCD when a consumer unit is replaced with a new one. Elsäkerhetsverket counts a straight replacement as maintenance, and then the rules from when the installation was built apply. The authority still recommends an RCD when the unit is replaced, because it raises safety for a small extra cost.

An RCD cuts the power quickly when current leaks to earth, in the installation or in a connected appliance. To protect people it must be marked 30 mA. A four-pole RCD from Hager for 25 A costs SEK 961 in the price list, or SEK 673 with ROT.

Two things are worth knowing. If the unit gets new circuits or new sockets at the same time, that is an extension of the installation, and that part must follow today’s rules. The RCD must also be tested with its test button at least twice a year. There is more about how it works in the guide to residual current devices.

How the replacement is done

A consumer unit is replaced in a set order, and the home is without power while the old unit is disconnected and the new one is connected.

  1. You send photos. The unit with the door open, the electricity meter and preferably the circuit chart, that is, the list of what each fuse supplies. Tell us if anything new is to be added, such as a charger or more sockets.
  2. We choose the size and you get a price. If the unit is in the price list, the fixed price applies.
  3. The power is switched off and the old unit is disconnected.
  4. The new unit is fitted and the wiring is connected. Each circuit gets its own breaker.
  5. The installation is inspected and tested before it is put into use. This is a requirement in Elsäkerhetsverket’s regulations for every new or altered installation.
  6. The unit is labelled and gets an up-to-date circuit chart. The electrical installation company is responsible for labelling and documenting the part it has worked on.

If the main fuse is to be raised or lowered at the same time, we file a notification with the grid operator (elnätsföretag), the company that owns the local grid, not the company you buy electricity from. The main fuse is the fuse that decides how much electricity the home can use at once. That work is described on the page about meter cabinets and main fuses.

Replacing the unit does not mean replacing the wiring

Wiring and sockets in good condition may stay when the unit is replaced, even if they were installed under older rules. Replacing the unit does not change what applies to the rest of the installation.

Their condition does show clearly when the unit is opened, though. If the insulation on the wires has visible damage or discolouration, the wires may be dangerous and need replacing, according to Elsäkerhetsverket. That work is not included in the fixed price for the unit. If you are renovating anyway, it can be wise to plan the electrics and the unit together, and that is described on the page about electrics when renovating.

The ROT deduction when the consumer unit is replaced

Installing and adding to consumer units is on the list of work that qualifies for the ROT deduction, kept by the Swedish Tax Agency, Skatteverket, both for houses (detached, semi-detached and terraced) and for tenant-owner flats (bostadsrätt). In 2026 the deduction is 30 per cent of the labour cost, up to SEK 50,000 per person per year. The unit itself and other materials give no deduction. So the difference between the price without and with ROT is less than 30 per cent of the whole price.

In a tenant-owner flat the deduction applies to a unit inside the flat that you are responsible for under the statutes (stadgar) of the tenant-owner association (bostadsrättsförening). Normally the tenant-owner is responsible for the electrics from the flat’s consumer unit inwards, but it is the statutes that decide. The guide to electrics in a tenant-owner flat sorts out where the line runs.

If the unit is replaced because the house is getting a charger, that part does not qualify for the Swedish tax reduction for green technology (grön teknik), but it can qualify for the ROT deduction. Companies and associations get no ROT deduction. We are based in Malmö and replace consumer units in Malmö and the rest of Skåne, for example consumer units in Malmö, consumer units in Lund and consumer units in Helsingborg.

Sources

Fixed prices

Materials, installation and VAT are included. A travel charge of SEK 500 is added.

Consumer unit
Job Price With ROT
Consumer unit 1×13 – Hager Gamma
SEK 5,810 SEK 4,780
Consumer unit 1×18 – Hager Gamma
SEK 6,578 SEK 5,503
Consumer unit 2×13 – Hager Gamma
SEK 8,627 SEK 7,079
Consumer unit 2×18 – Hager Gamma
SEK 10,020 SEK 8,236
Consumer unit 3×13 – Hager Gamma
SEK 10,689 SEK 8,625
Consumer unit 3×18 – Hager Gamma
SEK 10,689 SEK 8,625

All prices for consumer units

Common questions about consumer units

What does a new consumer unit cost with installation?

A Hager Gamma 1×13 costs SEK 5,810 installed, or SEK 4,780 with the ROT deduction. A 2×18 costs SEK 10,020, or SEK 8,236 with ROT. Materials, installation and VAT are included, and a travel charge of SEK 500 is added. The prices apply to a standard installation.

Is it illegal to keep an old fuse box with screw-in fuses?

No. According to Elsäkerhetsverket, an electrical installation must meet the requirements that applied when it was installed, and it does not have to be replaced just because it is old. Anything that is altered or added, on the other hand, must follow today's rules. If the fuse carriers get warm, you should have an electrical installation company look at the unit.

Does an RCD have to be fitted when the consumer unit is replaced?

No, there is no such requirement for a straight replacement. Elsäkerhetsverket counts the replacement as maintenance, and then the rules from when the installation was built apply. The authority still recommends an RCD when the unit is replaced, because it raises safety for a small extra cost.

What do 1×13 and 2×18 mean on a consumer unit?

The first number is the number of rows and the second the number of modules per row. So a 1×13 has one row of 13 modules, and a 2×18 has two rows of 18 modules each. A single-pole circuit breaker takes one module, a three-pole one takes three and a four-pole RCD takes four.

Is the home without power while the consumer unit is replaced?

Yes, the power is off while the old unit is disconnected and the new one is connected. How long depends on the size of the unit and the state of the wiring, so we do not give a time that applies to everyone. Plan for the fridge, the freezer and anything else that needs electricity to be without power during the work.

Am I allowed to replace fuses or the consumer unit myself?

You may replace a blown screw-in fuse with a new one of the same rated current, and reset a circuit breaker that has tripped. All other work in the unit must be done by an electrical installation company. That includes replacing circuit breakers, fitting an RCD and replacing the whole unit.

Does replacing the consumer unit qualify for the ROT deduction in a tenant-owner flat?

Yes, if the unit is inside the flat and you are responsible for it under the association's statutes. Skatteverket states that installing and adding to consumer units qualifies for the deduction. Work outside the home, for example in the stairwell, gives no deduction.

Can the new consumer unit be prepared for an EV charger?

Yes. Choose a unit with spare modules, because a three-phase charger needs a three-pole breaker. The charger must also have its own RCD, which can be built into the charger. Bear in mind that a new or extended consumer unit ahead of the charger does not qualify for the green technology reduction (grön teknik), but it can qualify for the ROT deduction.

Tell us what you need help with

Describe the job and feel free to attach photos of the consumer unit and the place. We will come back with questions if needed, and then with a price.