Underfloor heating and thermostat: replacing, fault-finding or laying new

You may replace an existing thermostat for no more than 16 A that sits in a box of its own with an equivalent one yourself, if you know how to do it. New 230 volt underfloor heating, however, you may not lay yourself. With us, a starter kit for 1 square metre with thermostat and sensor costs SEK 5,988 installed.

Electric underfloor heating consists of three parts, and different rules apply to them. The thermostat on the wall you may replace yourself under certain conditions. The cable in the floor you may not touch. Here you can read where the line runs, how a fault is narrowed down and what new underfloor heating costs.

The three parts of underfloor heating

  • The heating cable or heating mat is embedded in the floor and gets warm when current flows through it.
  • The floor sensor is a small temperature sensor that lies in the floor between the loops of the cable. It tells the thermostat how warm the floor is.
  • The thermostat sits on the wall. It switches the heating on and off so that the floor keeps the temperature you have set.

The thermostat and the sensor have to match. If the thermostat is replaced, the new one must work with the sensor that is already in the floor, and it must be able to handle the power of the heating cable. That is stated in the thermostat’s instructions.

When you may replace the thermostat yourself

You may replace an existing thermostat with an equivalent one. Koppla säkert (“connect safely”), the web service of the Swedish National Electrical Safety Board, Elsäkerhetsverket, puts it like this on its page about replacing a thermostat: you may replace a permanently connected thermostat for no more than 16 amperes, 400 volts, that is placed in an enclosure or box of its own, with one that has an equivalent function and connection.

Three conditions follow from that:

  1. It must be a replacement. A thermostat in a new place, a new box or a new cable is a change to the fixed installation.
  2. The new thermostat must be connected in the same way as the old one. A model that requires a different connection is not a straight replacement.
  3. You must know how to do it, and it must be possible to check the work. Elsäkerhetsverket writes that anyone who is the least bit unsure should leave the work to an electrical installation company (elinstallationsföretag).

Always switch off the power at the circuit’s fuse before you open the box, and check that there is no voltage. A circuit is the sockets and lights that share one fuse.

When the floor does not get warm

A cold floor usually has one of four causes. Go through them in this order.

What you see Likely cause Who does something about it
The thermostat is not lit at all The fuse or the residual current device (RCD) has tripped, or the thermostat is switched off You can reset the fuse yourself
The thermostat is lit but the floor is cold The setting, the thermostat or the heating cable Check the setting. After that, measurement is needed
The thermostat shows a fault or switches irregularly The floor sensor or the thermostat Electrical installation company
The RCD trips when the heating is switched on Current leaks to earth in the cable or in a connection Electrical installation company

When the simple things have been ruled out, the electrician measures the heating cable and the sensor separately. The measurement shows whether the cable is intact, whether it leaks current to earth and whether the sensor gives reasonable values. Only then is it possible to say whether a new thermostat is enough.

Fault-finding alone does not qualify for the Swedish ROT tax deduction for labour on your home (ROT-avdrag), and it has no fixed price with us. How fault-finding is done is described on the page about fault-finding and service.

When the RCD trips

An RCD cuts the power when current leaks to earth. If it trips every time the underfloor heating is switched on, it is doing what it should, and resetting it again and again does not help. Leave the fuse for the underfloor heating switched off until the fault has been investigated. The rest of the home works as usual in the meantime.

The same method as for other electrical faults works here: switch off all the fuses, reset the RCD and switch the fuses on one at a time. If it trips at the fuse for the underfloor heating, you have narrowed down the fault. The full walk-through is in the article when the RCD trips.

You do not lay new underfloor heating yourself

230 volt underfloor heating must be laid and connected by a registered electrical installation company. Elsäkerhetsverket writes on its page about installing underfloor heating that many people believe you can lay the cables yourself and have them inspected afterwards, but that this is not true. The reason is that part of the inspection has to be done before the floor is screeded or gets its floor covering.

This also applies to a new installation:

  • The underfloor heating must be protected by an RCD. If there is already an RCD for the whole house that also protects the underfloor heating, that is enough, according to Elsäkerhetsverket.
  • In bathrooms the heating cable must, according to SEK Svensk Elstandard, the Swedish electrical standards body, be covered by a metal sheath, a metal enclosure or a metal mesh that is connected to protective earth, that is, the conductor that leads current away in the event of a fault.
  • Never buy a product that lacks marking and installation instructions.

What applies in wet rooms is set out in the article on electrics in the bathroom.

What new underfloor heating costs

New underfloor heating has a fixed price with us. Materials, installation and 25 per cent VAT are included.

Line in the price list Price With ROT
Starter kit 1 square metre with thermostat, sensor and commissioning SEK 5,988 SEK 4,913
Extension, per additional square metre SEK 1,530 SEK 1,272
Combined RCD and circuit breaker (RCBO), 2-pole 10 A with small enclosure, if there is no RCD SEK 1,350 SEK 1,243

You pay for one starter kit and then one extension for each square metre beyond that. A travel charge of SEK 500 is added, and the prices apply to a standard installation. Screeding, the waterproofing membrane and the floor finish are your floor layer’s job. There is a worked example under underfloor heating and heating in the price list.

When to get in touch

Get in touch when the floor is cold even though the fuse is intact and the thermostat is correctly set, when the RCD trips or when the thermostat is to be moved. If you are planning a new floor, the electrician should be booked before the floor layer, not after.

We are based in Malmö and work in the rest of Skåne, and what applies where you live is on the page electrician in Malmö and in the overview of towns. If it is a straight replacement with an equivalent thermostat, and you know how to do it, you do not need an electrician.

Sources

Common questions

Can I replace the underfloor heating thermostat myself?

Yes, if it is a straight replacement. According to Elsäkerhetsverket's web service Koppla säkert, you may replace a permanently connected thermostat for no more than 16 amperes and 400 volts, which sits in an enclosure or box of its own, with one that has an equivalent function and connection. You must know how to do it. If you are unsure, an electrical installation company should do the replacement.

What does it cost to replace the underfloor heating thermostat?

Replacing the thermostat alone is not in our price list, so it gets a quote. The price depends on which thermostat is chosen and on whether it suits the sensor that is in the floor. The starter kit for new underfloor heating includes thermostat, sensor and commissioning, and it costs SEK 5,988 for the first square metre.

Why does the underfloor heating not get warm?

Start with the simple things: check that the fuse and the RCD are switched on and that the thermostat is switched on and correctly set. If all of that is in order, the fault is in the thermostat, the floor sensor or the heating cable. Which of them it is can only be determined by measurement, and that is done by an electrical installation company.

Can a damaged heating cable in the floor be repaired?

That depends on where the damage is and how the floor is built up. First the cable is measured, so that it is clear that the fault really is there and not in the thermostat or the sensor. After that it is possible to judge whether the damage can be reached and repaired or whether the underfloor heating needs to be relaid.

Does replacing a thermostat or new underfloor heating qualify for the ROT deduction?

We promise nothing. Underfloor heating and thermostats are not mentioned on Skatteverket's list of electrical work that qualifies for the deduction, and fault-finding alone explicitly gives no deduction. The price list shows the price with ROT for the underfloor heating, but the conditions can vary. Ask us or Skatteverket if you are unsure.

Can I lay low-voltage underfloor heating myself?

Laying heating cable or heating foil for safety extra-low voltage (SELV) of no more than 50 volts is exempt from the requirement for an electrical installation company. The exemption applies to the cable, not to a permanent connection of the transformer to 230 volts. In bathrooms special rules apply to extra-low voltage too, so take advice before you buy.

Tell us what you need help with

Describe the job and feel free to attach photos of the consumer unit and the place. We will come back with questions if needed, and then with a price.