Electric underfloor heating consists of three parts, and different rules apply to them. The thermostat on the wall you may replace yourself under certain conditions. The cable in the floor you may not touch. Here you can read where the line runs, how a fault is narrowed down and what new underfloor heating costs.
The three parts of underfloor heating
- The heating cable or heating mat is embedded in the floor and gets warm when current flows through it.
- The floor sensor is a small temperature sensor that lies in the floor between the loops of the cable. It tells the thermostat how warm the floor is.
- The thermostat sits on the wall. It switches the heating on and off so that the floor keeps the temperature you have set.
The thermostat and the sensor have to match. If the thermostat is replaced, the new one must work with the sensor that is already in the floor, and it must be able to handle the power of the heating cable. That is stated in the thermostat’s instructions.
When you may replace the thermostat yourself
You may replace an existing thermostat with an equivalent one. Koppla säkert (“connect safely”), the web service of the Swedish National Electrical Safety Board, Elsäkerhetsverket, puts it like this on its page about replacing a thermostat: you may replace a permanently connected thermostat for no more than 16 amperes, 400 volts, that is placed in an enclosure or box of its own, with one that has an equivalent function and connection.
Three conditions follow from that:
- It must be a replacement. A thermostat in a new place, a new box or a new cable is a change to the fixed installation.
- The new thermostat must be connected in the same way as the old one. A model that requires a different connection is not a straight replacement.
- You must know how to do it, and it must be possible to check the work. Elsäkerhetsverket writes that anyone who is the least bit unsure should leave the work to an electrical installation company (elinstallationsföretag).
Always switch off the power at the circuit’s fuse before you open the box, and check that there is no voltage. A circuit is the sockets and lights that share one fuse.
When the floor does not get warm
A cold floor usually has one of four causes. Go through them in this order.
| What you see | Likely cause | Who does something about it |
|---|---|---|
| The thermostat is not lit at all | The fuse or the residual current device (RCD) has tripped, or the thermostat is switched off | You can reset the fuse yourself |
| The thermostat is lit but the floor is cold | The setting, the thermostat or the heating cable | Check the setting. After that, measurement is needed |
| The thermostat shows a fault or switches irregularly | The floor sensor or the thermostat | Electrical installation company |
| The RCD trips when the heating is switched on | Current leaks to earth in the cable or in a connection | Electrical installation company |
When the simple things have been ruled out, the electrician measures the heating cable and the sensor separately. The measurement shows whether the cable is intact, whether it leaks current to earth and whether the sensor gives reasonable values. Only then is it possible to say whether a new thermostat is enough.
Fault-finding alone does not qualify for the Swedish ROT tax deduction for labour on your home (ROT-avdrag), and it has no fixed price with us. How fault-finding is done is described on the page about fault-finding and service.
When the RCD trips
An RCD cuts the power when current leaks to earth. If it trips every time the underfloor heating is switched on, it is doing what it should, and resetting it again and again does not help. Leave the fuse for the underfloor heating switched off until the fault has been investigated. The rest of the home works as usual in the meantime.
The same method as for other electrical faults works here: switch off all the fuses, reset the RCD and switch the fuses on one at a time. If it trips at the fuse for the underfloor heating, you have narrowed down the fault. The full walk-through is in the article when the RCD trips.
You do not lay new underfloor heating yourself
230 volt underfloor heating must be laid and connected by a registered electrical installation company. Elsäkerhetsverket writes on its page about installing underfloor heating that many people believe you can lay the cables yourself and have them inspected afterwards, but that this is not true. The reason is that part of the inspection has to be done before the floor is screeded or gets its floor covering.
This also applies to a new installation:
- The underfloor heating must be protected by an RCD. If there is already an RCD for the whole house that also protects the underfloor heating, that is enough, according to Elsäkerhetsverket.
- In bathrooms the heating cable must, according to SEK Svensk Elstandard, the Swedish electrical standards body, be covered by a metal sheath, a metal enclosure or a metal mesh that is connected to protective earth, that is, the conductor that leads current away in the event of a fault.
- Never buy a product that lacks marking and installation instructions.
What applies in wet rooms is set out in the article on electrics in the bathroom.
What new underfloor heating costs
New underfloor heating has a fixed price with us. Materials, installation and 25 per cent VAT are included.
| Line in the price list | Price | With ROT |
|---|---|---|
| Starter kit 1 square metre with thermostat, sensor and commissioning | SEK 5,988 | SEK 4,913 |
| Extension, per additional square metre | SEK 1,530 | SEK 1,272 |
| Combined RCD and circuit breaker (RCBO), 2-pole 10 A with small enclosure, if there is no RCD | SEK 1,350 | SEK 1,243 |
You pay for one starter kit and then one extension for each square metre beyond that. A travel charge of SEK 500 is added, and the prices apply to a standard installation. Screeding, the waterproofing membrane and the floor finish are your floor layer’s job. There is a worked example under underfloor heating and heating in the price list.
When to get in touch
Get in touch when the floor is cold even though the fuse is intact and the thermostat is correctly set, when the RCD trips or when the thermostat is to be moved. If you are planning a new floor, the electrician should be booked before the floor layer, not after.
We are based in Malmö and work in the rest of Skåne, and what applies where you live is on the page electrician in Malmö and in the overview of towns. If it is a straight replacement with an equivalent thermostat, and you know how to do it, you do not need an electrician.
Sources
- Elsäkerhetsverket – Koppla säkert, replacing a thermostat (in Swedish)
- Elsäkerhetsverket – Installing underfloor heating (in Swedish)
- Elsäkerhetsverket – Does the electrical installation company have to make sure the new underfloor heating in the bathroom is protected by an RCD? (in Swedish)
- Elsäkerhetsverket – What may I do myself with electricity? (in Swedish)
- SEK Svensk Elstandard – Electrical installations in bathrooms, 2023 (in Swedish)
- Elsäkerhetsverket's regulations on electrical installation work, ELSÄK-FS 2017:2 (in Swedish)
- Skatteverket – Does the work qualify for the ROT deduction? (in Swedish)