Replacing a consumer unit in Lund

We replace and extend consumer units in Lund municipality. Four in ten houses here were built in 1961–1980. Age in itself is no reason to replace a unit. A reason that does hold is that the house has been given more to supply than the unit has room for.

Close-up of breakers on a rail in an electrical cabinet
From us in Malmö
21 km, about 22 min by car
Places we work in include
Lund, Dalby, Södra Sandby, Veberöd, Genarp, Stångby

When the house needs more circuits than the unit has

Lund municipality has 19,520 homes in houses (detached, semi-detached and terraced). 7,605 of them, 39.0 per cent, are in houses built in 1961–1980, and the largest single group is from 1971–1980. If the consumer unit is still the one from the year the house was built, it is between 46 and 65 years old today.

Age is no reason in itself. The Swedish National Electrical Safety Board, Elsäkerhetsverket, writes that an electrical installation must meet the requirements that applied when it was installed and does not have to be replaced just because it is old. A reason that does hold is that the house gets more to supply than the unit has room for:

  • an EV charger (wallbox), which should have its own circuit
  • a new kitchen with more and larger appliances
  • an extension to the house or a converted garage
  • a move from single-phase to three-phase, where the house gets three live conductors instead of one

A circuit is the sockets and lights that share one fuse. When every space in the unit is taken there are two ways forward: add a smaller unit next to it, or replace it with a larger one.

Replacement is maintenance, extension is something else

The rules distinguish between two things. If an existing unit is replaced with a new one with the same circuits, it counts as maintenance. Then the rules from when the installation was built apply, and there is no requirement for a residual current device (RCD). Elsäkerhetsverket still recommends that you fit one when the unit is replaced. An RCD cuts the power when current leaks to earth.

If new circuits or new sockets are added, it is an extension. The new part must follow today’s rules, however old the rest of the installation is. The difference between a screw-in fuse and a circuit breaker, a fuse that can be switched back on after it has tripped, is covered in the guide fuse box (proppskåp) or circuit breakers.

Size and price

Hager Gamma Price With ROT
One row, 13 modules SEK 5,810 SEK 4,780
Two rows, 13 modules per row SEK 8,627 SEK 7,079
Three rows, 13 modules per row SEK 10,689 SEK 8,625
Four rows, 52 modules SEK 13,794 SEK 11,214

The prices include materials, installation and VAT and apply to a standard installation. A travel charge of SEK 500 is added. In 2026 the Swedish ROT tax deduction for labour on your home (ROT-avdrag) is 30 per cent of the labour cost, up to SEK 50,000 per person per year. Installing or adding to a consumer unit is on the list of work that qualifies for the deduction, kept by the Swedish Tax Agency, Skatteverket. Other sizes are on the page with fixed prices for consumer units.

Three grid operators when the main fuse is changed

Replacing the consumer unit does not change the main fuse, which decides how much electricity the whole house can use at the same time. If you want to raise it at the same time, or go from single-phase to three-phase, a notification has to go to the grid operator (elnätsföretag), the company that owns the local grid, not the company you buy electricity from. Which company that is depends on where you live:

  • The town of Lund: Kraftringen Nät. A change of fuse is on the company’s list of work that must be notified. Kraftringen also writes that a larger fuse means a higher fuse-based fee (säkringsavgift), and that the change from single-phase to three-phase carries a charge equal to the company’s actual costs.
  • Dalby, Södra Sandby and Genarp: as a rule Skånska Energi Nät.
  • Veberöd: E.ON, according to the map of grid areas.

The boundaries do not follow the towns, so the bill from your grid operator gives the sure answer. Raising or lowering the main fuse between 16, 20 and 25 A is in the price list at SEK 686 with pre-notification and completion notice (för- och färdiganmälan), that is, a notification to the grid operator both before and after the work. The background is in the guide to going from single-phase to three-phase.

The flats, new and old

Lund has built a great deal in recent years. 8,286 of the flats in blocks of flats, 21.4 per cent, are in buildings from 2011 or later. They have had RCDs from the start, because these have been required in new homes since 1 January 2000. At the other end there are 5,736 flats in buildings from before 1941.

20,125 of the flats are tenant-owner flats (bostadsrätt). There the statutes (stadgar) of the tenant-owner association (bostadsrättsförening) decide who is responsible for the consumer unit, and normally it is you, from the flat’s consumer unit inwards.

From Malmö to Lund Central Station it is 21.1 kilometres. How the work itself is done is described on the page about replacing a consumer unit.

More in Lund

Common questions about replacing a consumer unit in Lund

Does the consumer unit have to be replaced when I install an EV charger at my house in Lund?

Only if it has no room for a new circuit for the charger. If there is a free space, it is often enough to add to the unit. If the unit has to be extended or replaced, that part does not qualify for the Swedish tax reduction for green technology (grön teknik), but it can qualify for the ROT deduction on the labour cost.

Does Kraftringen need to be contacted when the consumer unit is replaced?

That depends on what is changed. Kraftringen lists a change of fuse, a change to the service cable and a broken seal among the jobs that must be notified. Replacing the consumer unit is not on that list. We go through the installation and file the notification when it is required.

Our house in Södra Sandby has an old fuse box with screw-in fuses. Can it stay?

Yes. An old fuse box with screw-in fuses (proppskåp) is not prohibited, and an older installation in good condition does not have to be replaced. You may replace a blown screw-in fuse yourself with a new one of the same rated current. Fuse carriers that are too hot to touch, or fuses that trip often, are on the other hand signs that an electrical installation company (elinstallationsföretag) should look at.

How large a consumer unit does a seventies house in Lund need?

That is decided by the number of circuits, not by the year the house was built. Count the fuses you have today and add what you are planning, for example an EV charger or a new kitchen. A single-pole circuit breaker takes one module, while three-phase circuits and residual current devices (RCDs) take more. A unit with two rows and 13 modules per row costs SEK 8,627.

Tell us what you need help with

Describe the job and feel free to attach photos of the consumer unit and the place. We will come back with questions if needed, and then with a price.