Skip to content
079-350 31 43

Fault-finding step by step when the RCD trips

When the residual current device (RCD) trips, current is leaking to earth somewhere, in an appliance or in the fixed installation. You can narrow down where yourself: switch off all the circuits, switch the RCD back on and then switch on one circuit at a time. If the fault is in an appliance, it is often enough to unplug it.

A residual current device (RCD) that trips has done its job. It has sensed that current is leaking to earth, and the fault is either in an appliance or in the fixed installation. Which it is you can find out yourself, without tools and without opening anything. The method is the same one that the Swedish National Electrical Safety Board, Elsäkerhetsverket, describes on its page about the RCD: try one fuse at a time.

Before you start

Everything in this fault-finding is done with handles, toggles, screw-in fuses and plugs. Those are things that are made for you to touch.

  • Stand somewhere dry and have good light at the consumer unit.
  • If there is a smell of burning, or something looks discoloured, do not switch anything on. Leave the RCD off and call an electrical installation company (elinstallationsföretag).
  • Get out the circuit chart. That is the list by the consumer unit that shows what each fuse supplies. A circuit is the sockets and lights that share one fuse.
  • Do not unscrew covers, sockets or boxes. That is not needed to find the fault.

You recognise the RCD by its test button, which is usually marked T or Test. The RCD is wider than a single circuit breaker.

Fault-finding step by step

  1. Switch off all the circuits. Flip down all the circuit breakers. If you have screw-in fuses, unscrew them. A circuit breaker is a fuse that switches off and can be switched on again.
  2. Switch the RCD on. If it stays on, move on. If it cannot be switched on even now, skip to the section on when it cannot be switched on.
  3. Switch on one circuit at a time. Wait a few seconds between each. When the RCD trips, you have found the circuit with the fault.
  4. Give the rest of the house power. Switch off the faulty circuit, switch the RCD on and switch on the other circuits. Now everything works except that circuit.
  5. Unplug everything on the faulty circuit. The circuit chart shows which rooms and sockets are involved. Do not forget the things that are rarely seen: dishwasher, washing machine, fridge and freezer, engine heater, pumps and outdoor lighting with a plug.
  6. Switch the circuit on again. If the RCD holds, the fault is in one of the appliances you unplugged.
  7. Plug in one appliance at a time. The one that makes the RCD trip is the faulty one. Do not use it until it has been repaired.
  8. Does it trip with everything unplugged? Then the fault is in the fixed installation, or in something that is permanently connected. Leave the circuit switched off and call in an electrical installation company.

Elsäkerhetsverket sums up the logic like this: if the RCD trips when you have screwed in a particular fuse or switched on a particular circuit breaker, “the fault is probably in the part of the electrical installation that is protected by that particular fuse or circuit breaker”.

Common patterns and what they point to

How and when the RCD trips says a good deal about where the fault is.

Pattern Likely cause What you do
Trips when a particular appliance starts Insulation fault in the appliance. Common in appliances with heating elements, such as kettles, irons, dishwashers and washing machines Unplug the appliance and have it repaired or replace it
Trips in rain or damp weather Moisture in an outdoor socket, light fitting, junction box or extension lead outdoors Unplug everything in the outdoor sockets. Fixed parts need an electrician
Trips during a thunderstorm Interference from the thunderstorm Switch on again. If it does not happen again, nothing needs to be done
Trips now and then, often at night An appliance that starts by itself, such as a fridge, freezer or water heater Write down the times and compare with what is running then
Trips when you switch on a particular light Fault in the light fitting or in the cable to it Leave the circuit off and call an electrician
Trips after someone has been drilling or nailing A cable in the wall may be damaged Leave the circuit off and call an electrician
Cannot be switched on at all Permanent fault in the installation, or a fault in the RCD Call an electrician

Two things often come as a surprise. The first is that the RCD can trip without anything being switched on. The RCD measures leakage current, not consumption, and a damp box leaks whether the light is on or not. The second is that several appliances that each leak a little can trip the RCD together, even though none of them is faulty. Then it helps to spread them out so that they are not on the same RCD, if the house has more than one.

When it cannot be switched on

If the RCD cannot be switched on even with all the circuits off, there are two common explanations. One is that the RCD itself is faulty. The other is a fault between neutral and protective earth somewhere in the house. The neutral is the conductor that carries the current back, and the protective earth is the conductor that leads current away in the event of a fault. An ordinary fuse only breaks the phase conductor, the live conductor, and the neutral conductor is therefore still connected when the fuse is off.

You can make just one more attempt on your own: pull out every plug in the whole house and try again. If the RCD holds then, you have an appliance to look for. If it does not, someone needs to take measurements in the installation, and that is a job for an electrical installation company.

What you should not do

  • Never bypass the RCD and never hold the handle in place. Then you remove the protection just when it is needed.
  • Do not switch it on again and again in the hope that it will hold. Every attempt puts voltage on the fault.
  • Do not move the faulty appliance to a socket that has no RCD. The fault is still there, but now it goes unnoticed.
  • Do not open the consumer unit, sockets or boxes to look. Repairing the fixed installation is electrical installation work.

Test the RCD when the fault is gone

When everything works again, it is a good moment to press the test button. The power should be cut. Elsäkerhetsverket recommends that you do so at least twice a year. If the button does not cut the power, the authority’s answer is short: “Call in a registered electrical installation company as soon as possible.”

There is more about how the RCD works and when it is required in the article on residual current devices. If it is an ordinary fuse that trips, and not the RCD, the cause is overload or a short circuit. That is described in the article on when the fuse keeps tripping.

Who is responsible for the fault

  • Detached house, terraced house and holiday home. As the owner of the house you are the holder of the electrical installation (innehavare) and responsible for it.
  • Tenant-owner flat (bostadsrätt). Normally you are responsible for the electrics from the flat’s consumer unit inwards, but the association’s statutes (stadgar) decide.
  • Rented flat. In most cases the landlord is the holder. Do the fault-finding up to step 7 and report the fault if it is not in one of your own appliances.

When to get in touch

If you found a faulty appliance, you do not need an electrician. Get in touch when the fault is in the fixed installation, when the RCD cannot be switched on or when it trips without a pattern. Tell us which circuit it is, what was running, what the weather was like and what you have already tried. That shortens the time we need to find the fault. The work is described on the page about fault-finding and service.

Fault-finding is not included in the fixed prices, because the time depends on the fault, and fault-finding alone does not qualify for the Swedish ROT tax deduction for labour on your home (ROT-avdrag). If it turns out that the RCD itself has to be replaced, a new four-pole 25 A RCD costs SEK 961, with materials, installation and VAT. A travel charge of SEK 500 is added. That line and other accessories are under consumer units in the price list.

Sources

Common questions

Why does the RCD keep tripping?

Because current leaks to earth every time the RCD is switched on. Common causes are an appliance with an insulation fault and moisture in something that sits outdoors. Switch off all the circuits and switch them on one at a time, and you will see which circuit the fault is on. Then unplug the appliances on that circuit.

Can I switch the RCD back on myself?

Yes. The fault-finding method from the Swedish National Electrical Safety Board, Elsäkerhetsverket, is itself based on your switching the RCD on and trying one fuse at a time. If it trips again straight away, do not keep trying. Fault-find circuit by circuit instead, and leave the faulty circuit switched off until the fault has been found.

Why does the RCD trip when it rains?

Then it is usually moisture that has got into something outdoors: a socket, a light fitting, a junction box or an extension lead. Unplug everything in the outdoor sockets and try again. If the RCD holds, you have found the fault. If the fault is in a fixed installation, an electrical installation company must put it right.

The RCD trips even though all the fuses are off, what is the reason?

An ordinary fuse only breaks the phase conductor. The neutral conductor is still connected, and a fault between neutral and protective earth can therefore make the RCD trip even when the circuit's fuse is off. There may also be a fault in the RCD itself. In both cases an electrical installation company needs to take measurements.

What do I do if the test button does not cut the power?

Then you cannot rely on the RCD. Elsäkerhetsverket's answer is to call in a registered electrical installation company as soon as possible. Be extra careful with appliances in the bathroom and outdoors until then, and do not use any appliances that you know are damaged.

When should I stop fault-finding myself and call an electrician?

When the RCD trips even though all the plugs on the circuit are pulled out, when it cannot be switched on at all, when there is a smell of burning or when the fault comes and goes without a pattern. Then the fault is in the fixed installation or is hard to find without measuring instruments.

Tell us what you need help with

Describe the job and feel free to attach photos of the consumer unit and the place. We will come back with questions if needed, and then with a price.